Tuesday, December 05, 2017

MORE GIFTS FOR SAILORS





Here is another gift suggestion for any boater who has a dingy or rowboat. An ATTWOOD PORTABLE PUMP. I use one and it beats using a hand pump to empty a dingy after a rain or in my case one that had a hard to find slow leak. Could also be used to drain water tanks and coolers. Any boater would be pleased to have this handy pump around to help drain things quickly and effortlessly.

Sunday, June 21, 2015

A WASTE OF TIME

Sometimes you just have to know when to stop doing some optional maintenance that is going to turn out to be more of a problem than it's worth. A while ago I had two equipment failures located in the same area and sharing the same wiring. One was the anchor washdown pump and the other was the Jabsco macerator pump. Since they both were fed from the same breaker and stopped working at the same time I thought it was too much of a coincidence that they both would fail at the same time. It was not. I worked on the Flojet washdown pump first and found it's problem was a faulty corroded pressure switch. Then a week ago I decided to finally take a look at the macerator pump issue. Since I thought at first it might be a power issue I decided to rewire the pump using Anderson Power Pole connectors. Using the30 amp connectors would make removing and testing the pump easier now and in the future. It would also help clean up some of the wiring. The macerator pump power was originally operated through a on/off /on switch that powered the washdown pump or the macerator pump depending on which position the switch was set:

So I wired two Powerpole connectors directly to the pump power wires:


I found some trouble shooting info on one of the sailing websites that some times the macerator pump is jammed. But, there is a cap on the back of the motor that could be removed and a screwdriver inserted onto the macerator pump motor shaft to turn it and clear the jam. Unfortunately, my twenty eight year old pump must have been one of the early ones and did not have the mentioned cap. So it looks like I will have to remove the pump to investigate further. In addition a ball valve on the output of the pump was jammed and would not budge. Since the input to the macerator pump also had a T that also connected to the holding tank output. Taking the pump out would now make the holding tank unable to be emptied by the usual means like a pump out:

So I decided that this project would be best done in the off season when I have more time to deal with working in the confined space where these components are located. My time is better spent now getting the boat ready for launching for the season. Sometimes you just have to know when to stop on some projects.

Thursday, March 13, 2014

THAT SINKING FEELING

On occasion I will have a dream that my boat is sinking for no reason or doing something impossible like moving along a creek bed. Though one time it was moving through the streets of Manhattan. Strange that these dreams seem to only happen when I'm not living on board. They are sometimes very disturbing (especially the sinking ones) that is until I come awake and realize they were just dreams. But, for some unfortunate sailors in St. Martin recently it was not a dream:

)


Sunday, September 29, 2013

PUMP IT UP: Repairing a FloJet 4300 Series Washdown Pump. Part Two

After diagnosing the problem with BIANKA's FloJet washdown pump and losing and then finding the replacement pressure switch. I was finally able to start the repair. The first issue to surface was to find which replacement pressure switch kit to use as there are several available. I contacted FloJet customer service who requested the model number and serial number for my pump. It turns out I need the  Flojet 02090118 40 PSI Pump Switch Kit for my model 4305-143 FloJet pump. Included with the replacement pump kit is a list of FloJet models and there replacement switch part numbers:

My FloJet pump has been on the boat since I bought it in 1995 and probably longer perhaps as far back as 1986. In the time since FloJet has changed the design of the pressure switch and as a result there are less parts involved and some that are eliminated altogether. The instructions show which parts need to be removed and how to install the new ones:

Here is what my pumped looked like after I removed the old pressure switch and the parts I would be discarding:


Here is what comes with the new replacement pressure switch kit:


Much less parts to deal with than the old pump. There are three pump diaphragms that come with the new kit:


As explained in the instructions which one you use depends on the liquid that will be flowing through the pump. They are labeled V, B and E. Which stand for Viton, Buna and EPDM. For potable water and seawater the instructions say to use the diaphragm labeled E for EPDM. There are some subtle changes in the replacement diaphragms too.  Here is a new Buna diaphragm on the right compared to the old diaphragm removed from the pump on the left. Notice that the lip on the new diaphragm is a little different. So it is best to discard the old one and not keep it around as a spare:

Here is the new EPDM diaphragm installed on the pump:

The new  Flojet 02090118 40 PSI Pump Switch  comes with black wires attached:


I swapped them with the red wires (also included in the replacement kit) since the switch will be switch the + 12 volt voltage:

Once the EPDM diaphragm was installed on the pump body one carefully aligns the switch module so that the diaphragm is not pinched  and screw holes are aligned and screws one screw snug and then the other to about 9-10 inch pounds. I just snugged them by feel and had no leaks.

In addition to replacing the switch I also took the opportunity to add Anderson Powerpole connector to the pump and switch wires. This will make it easier to troubleshoot the switch or even by pass the switch completely:

With the new pressure switch installed and Powerpole connectors installed the pump is ready to be reinstalled:


I was curious about the defective pressure switch. I had to cut the plastic off of the switch area and took a look at it after it was removed and it was a little more complicated than I imagined:

There are springs and two contacts that connect to each of the terminals. The failure of the switch seemed to be a combination of corrosion and bad contacts. Still it lasted eighteen plus years without a problem. Hopefully the replacement will last just as long.


Tuesday, September 03, 2013

PUMP IT UP: Repairing a FloJet 4300 Series Washdown Pump Part One

Pump it up until you can feel it.
Pump it up when you don't really need it.
 Elvis Costello

At the end of last season I discovered two of the four electric pumps on board BIANKA did not work. They both were feed from the same circuit breaker but, do not operate at the same time. One was the Wash Down pump used to clean the anchor chain after it's been laying on mucky bottoms. The other was the Macerator pump that is used usually once a year on haul out after I rinse out the holding tank. Neither one would power up. Sounded to me like a power issue since both pumps were fed from the same circuit. Having two pumps fail at the same time seemed against the odds. Sounded to to be an easy fix. Most likely a power issue.  First I measured the voltage from the circuit breaker panel it read the nominal 12 volts. Well, then gotta be the switch that switches between which of the pumps will be energized. But, when I checked the switch it was good. Oh well. Looks like both pumps did fail at the same time. Since one pump was for the wash down and used every time I hoist the anchor and the other pump was for the macerator and really only used one time each year when cleaning and winterizing the holding tank for storage. I decide the wash down pump was the priority.

The wash down pump is a Flojet 4300 series pump. A 4305-143 to be precise and had been on the boat since I bought her in 1995. It had worked well until now. The pump is located in behind a panel the head area along with the pressure water pump and the shower sump pump:


Pretty easy to get to unlike the macerator pump which is buried under some cabinetry and hoses. Though because all the wiring was connected with crimped splices I had to cut the wires to remove the pump from the cabinet. But, I decided to rewire the pump with Anderson Powerpole connectors to make future removal of the pump and trouble shooting easier.

After removing the pump I looked for anything obvious that might have caused the failure:

Not seeing anything suspicious I followed red 12 volt lead that went into a small module on the pump and exited out the other side and connected to the motor. The is the pressure switch that shuts off the pump when the pressure reaches a certain level. Taking the cover off of this module exposed it's connections:
Nothing unusual but, I did notice a little melting and discoloration of the wire and some melting on the housing of the switch:


Well this certainly was worth investigating. The connections to the wires looked good but, when I took out my meter and measured across them I found a high resistance across the leads:

I measured 4 meg ohms not a totally open circuit but, high enough to prevent the pump  from operating. I decided to first remove the spade connectors clean the contacts to see if that improved the readings:


Having done that I still measured a high resistance. So I decided to remove the pressure switch module from the body of the pump:


I had no parts diagram of this part of the pump so I could not be sure how things were supposed to look. But, when I went back and measured across the leads of the pressure switch I read about three ohms so that seemed to be normal. I put the pressure switch module back on to the pump and reinstalled the pump back into the locker. After connecting the wash down hose I applied power and the pump began gushing out water. Ah, fixed I thought. I shut down the power put a nozzle onto the hose and fired up the pump again. I could hear the pump as it pressurized the hose and then shutdown like it should. But after opening the nozzle and relieving the pressure the pump still  failed to turn on.  So it looks like I'll need to do a little more troubleshooting but, before I do I will get a replacement pressure switch. Since that looks like where the problem is. Though the documentation shows there is not such part. It looks like I may need to order a whole upper housing. I'll be making a call into FloJet customer service to see if this is the case before I continue.

FOR  PART TWO OF THE PUMP REPAIR CLICK HERE






Sunday, April 14, 2013

TROUBLE DOWN BELOW: Bilge Pump Switch

I mentioned that after the two plus feet of snow that the blizzard NEMO dumped on the Isle of Long I found BIANKA's bilge half filled with water when I finally was able to check on the boat. Since I could empty the water by activating the bilge pump with the manual switch it was apparent the automatic bilge switch was the problem:

Because of some freelance work commitments I was not able to replace the switch for several weeks. I emptied the bilge and hoped for the best. When I finally got back to the boat yesterday I was glad to find only about an a half inch of water in the bilge. It seems the blowing snow of the blizzard had found some ways into the boat where normal rains do not.  The bilge switch that failed was a Rule Super Switch that had worked reliably since I bought BIANKA in 1995 and may have been installed when the boat was commissioned in 1986. So it had a pretty long life in the Marine environment. When I remove the switch I was surprised to find there were two parts that made up the bilge switch. There was the float switch it's self and an optional guard case that it fit into:


Since I never had to mess with it in seventeen years it came as a surprise. The case helps keep debris away from the floating switch and also has a button you can push to test the switch to make sure it is working. This helps to make sure any debris will not cause the switch to stick in either on or off position.

In my researching for a new bilge pump switch I read several reviews the the newer bilge pump switches were a little more trouble prone. As they changed from a mercury switch to a metal ball conducting between to contacts. Some reviews mention the switches not lasting too long before failures. So I look at other choices and settled on  a Water Witch 101 control.


The Water Witch is an electronic switch the senses water between two electrodes to turn the bilge pump on. It was also considerably smaller than the Rule switch it was replacing:


The install was pretty simple and the manufacturers web site had a diagram on how to wire it up for my particular installation. I have a switch panel on board where I can manually power the bilge pump via a switch or switch it over and have a bilge switch automatically turn the bilge pump on once the water rises.
I used  Anderson Powerpole Connectors to connect the switch and bilge pump. This will allow for easier trouble shooting and/or replacement in the future.


I waterproofed the connectors with some   Marine Adhesive Goop and will further waterproof it later with some heat shrink and additional sealant in the near future. With the units wired up I tested it by putting the switch into a plastic cup and then added some water:


The pump operated as expected after a short delay to prevent cycling of the pump the bilge pump turned on. I then removed the switch from the water:

Again after a short delay it turned off. Convinced that the switch was working correctly I installed it into the bilge by attaching the switch unit to the bilge pump hose with a cable ty:


Well that's one pre launch project finished now on to the next one.